Tips for Installing Stainless Steel Rigid Conduit

Expert Tips for Cutting, Threading & Bending Stainless Steel Rigid Conduit

When it comes to industrial and corrosive environments, stainless steel rigid conduit systems are the go-to choice for many electrical professionals. Here at Team Electrical Supply in the Detroit area, we’re excited to share our expertise on this robust electrical conduit option.

Stainless steel rigid conduit boasts a greater wall thickness than IMC or EMT, making it ideal for demanding applications. Its threaded connections not only ensure electrically continuous joints but also allow for easy installation and system durability. So, let’s debunk a common myth right off the bat: working with stainless steel conduit in the field isn’t as challenging as you might think!

Contrary to popular belief, you don’t necessarily need specialized threaders or benders to work with and install rigid conduit. In most case, common field tools will do the job just fine. This means you can save time, labor, and costs without compromising on quality. While there are a few special considerations for stainless steel, the installation process is quite similar to working with galvanized rigid conduit (GRC).

To ensure your stainless-steel rigid conduit system performs as expected, it’s crucial to follow all relevant National Electric Code (NEC) guidelines. Don’t forget to review the operating and safety instructions that come with your equipment, too. And proper handling during pre-installation alterations like cutting, threading, and bending is key. If these steps aren’t done correctly, you might find yourself facing a more difficult, time-consuming, or costly installation process. Even worse, it could impact the longevity of your conduit system.

In this article the expert stainless steel rigid conduit suppliers at Team Electrical Supply in the Detroit area provide some tips for cutting, threading, or bending rigid conduit in the field.

Getting Started Installing Stainless Steel Rigid Conduit

Before you dive into cutting, threading, or bending stainless steel conduit, there’s an important rule of thumb to remember: all equipment that comes into contact with the conduit should be either new or used exclusively on stainless steel. This includes bending shoes and vises. Why? Using equipment that has processed ferrous material can transfer free iron to the stainless steel, leading to rust and corrosion down the line.

And, of course, always be sure to install rigid conduit in accordance with NEC guidelines. When you’re facing unique installation challenges that require field alterations, it’s best to review NFPA 70 (National Electric Code®) and consult local experts, including your Authority Having Jurisdiction (AHJ). This extra step ensures your conduit system is safe, effective, and built to last.

Additionally, be sure to purchase your stainless steel rigid conduit from a reputable supplier, like Team Electrical Supply in the Detroit area. This ensures that you get authentic parts of the highest quality, at the best possible prices. As with anything, you get what you pay for – and conduit from less-than-reputable sources may be made of substandard materials that don’t hold up to your projects exacting standards.

Tips for Cutting Stainless Steel Rigid Conduit

Precision is key when cutting rigid conduit. Even small measurement errors can add up, significantly impacting your overall installation. Here’s a pro tip: always mount your rigid conduit firmly and securely in a vise before cutting. Yes, it takes a bit more time, but skipping this step can lead to disaster.

Cutting unsecured rigid conduit isn’t just unsafe – it can result in crooked or rough cuts that make threading and assembly much more challenging, if not impossible.

Tips for Threading Stainless Steel Rigid Conduit

If you’re using threaded fittings, proper threading is crucial for secure connections. The good news is that you can use standard threaders on stainless steel rigid conduit. However, keep in mind that standard dies will wear out faster, especially when working with larger conduit sizes (2-½”, 3″, 4″). Keep a close eye on your dies and replace them if they show signs of wear.

Here’s another insider tip: when threading stainless conduit with standard dies, it’s best to use a new die set. Dies previously used on non-stainless pipe can cause material transfer, potentially leading to corrosion down the line.

You can thread rigid conduit using either manual or powered tooling. Manual tooling works well for smaller trade sizes of pipe (½” – 2″). Most threading equipment comes with detailed manuals – keep these handy and refer to them throughout the process for best results.

Tips for Bending Stainless Steel Rigid Conduit

While manufacturers often offer factory-bent elbows, the diverse configurations of conduit installations mean you’ll likely need to make some bends in the field from time to time. With experience and the right equipment, you can fabricate various bend shapes quickly and efficiently, right on-site.

The NEC allows for up to 360° of bends between pulling points, but remember: every degree of bend makes wire pulling more challenging and increases wire strain. As a best practice, aim to make as few bends as possible, and avoid making any single bend greater than 90°.

Before you start bending, double-check that your equipment is rated for use with rigid conduit. This precaution helps reduce the risk of equipment damage and accidents. Power benders, in particular, generate a lot of potential energy and can cause severe injuries if used improperly.

You can bend stainless steel using a standard rigid conduit bender, but be prepared for a greater degree of spring-back, especially with larger sizes (2″ or larger). Most bending equipment comes with detailed manuals – keep these on hand and refer to them before starting and throughout the process.

Final Tips for Installing Stainless Steel Rigid Conduit

We can’t stress this enough: when working with stainless steel conduit, all equipment that comes into contact with it should be either new or used exclusively on stainless steel. This includes bending shoes and vises. Equipment that has processed ferrous material can contaminate the stainless steel surface with free iron, leading to rust and corrosion.

Here’s some more good news: skilled industrial electricians can install stainless steel conduit without labor-intensive procedures like sealing, sprays, paint, or surface treatments. This reduces the maintenance burden on facility owners and operators, cutting down on periodic inspections and upkeep costs. When installed correctly, a stainless steel rigid conduit system can last as long as the facility itself, even in corrosive environments.

For unique installation challenges requiring field alterations, always review NFPA 70 (National Electric Code) and consult local experts, including your AHJ. This ensures your conduit system is safe, effective, and built to stand the test of time.

Stainless Steel Rigid Conduit Suppliers | Detroit Area

At Team Electrical Supply in the Detroit area, we’re proud to offer a comprehensive range of stainless steel rigid conduit products. Our inventory includes rigid conduit (also known as heavywall), nipples, and 90° elbows. But that’s not all – we also stock the widest array of additional fittings you’ll need to construct a complete stainless steel conduit system.

Whether you’re tackling a new installation or upgrading an existing system, our knowledgeable electrical supply staff is here to help you select the right products for your specific needs. We understand the unique challenges of working with stainless steel rigid conduit and are committed to providing not just high-quality products, but also the expertise to ensure your project’s success.

Don’t let misconceptions about stainless steel rigid conduit installation hold you back. With the right tools, techniques, and support from Team Electrical Supply, you can confidently tackle even the most demanding industrial electrical installations. If you are in the Detroit area, or anywhere in Southeast Michigan, contact us today to learn more about our stainless steel rigid conduit offerings and how we can support your next project. Let’s work together to build electrical systems that stand the test of time, even in the most challenging environments.

Rigid Conduit Supplier | Detroit Area: 313-874-1000